Maintenance
126 Avaya CMS Sun Ultra 5 Computer Hardware Installation, Maintenance, and Troubleshooting
Administering a replacement data disk, R3V8 and earlier
To administer a new data disk drive that is a replacement for a defective data disk drive:
1. Verify that the disk has been partitioned.
2. Enter the following commands to set the path variables:
PATH=$PATH:/usr/opt/SUNWmd/sbin:/olds
export PATH
3. Enter:
olds -check_disks
This checks the disk partitioning.
A message similar to the following is displayed:
4. Enter:
olds -mk_files
The following message is displayed:
5. Enter:
olds -metadbs
This sets up the metadevices. Ignore any error messages about failures while
activating new replicas.
disk:cot0d0 is partitioned ok
disk:cot1d0 is partitioned ok
disk:cot2d0 is partitioned ok
Warning: Current Disk has mounted partitions
disk:cot0d0 is partitioned ok
Success, checking disks
#
Success, creating md.tab.new and/or vfstab.new
#