Example:
snmp-server informs
User level: supervisor
Use the snmp-server informs command to configure inform parameters.
udp-port
(Optional)
Keyword that specifies that a specific UDP port on the target
host should be used when sending notifications to the host.
The default UDP port is 162.
port The UDP port on the target host to which notifications are sent.
notification
-type-list
(Optional)
List of notification types. Each types combines related
notifications. You can enable or disable notification generations
on a per group basis. For example, the swRedundancy type
groups new and delete software redundancy notifications.
If no notification-type-list is specified, the default, all, is used.
all/* – All traps
generic – Generic traps
config – Config change notifications
eth-port-faults – Ethernet port fault notifications
sw-redundancy – Software redundancy notifications
temperature – Temperature warning notifications
cam-change – Changes in CAM notifications
l3-faults – Layer 3 faults, including duplicate IP and
VLAN violations
lag-event – Link aggregation faults and configuration
changes
policy – Changes in policy notifications (for L3 devices)
link-down-faults – ITC proprietary link down
notifications
supply – Power supply notifications (main and backup)
fan – FAN faults notifications (main and backup)
cascade – Cascade connection fault notifications.
Note that the list of notification names is proprietary to ITC.
P330-N>snmp-server host 149.49.38.221 informs v3 noauth
charlieBrown