Chapter 2 Avaya P330-ML Layer 2 CLI Commands
56 Avaya P330-ML Reference Guide
rmon alarm
User level: privileged, supervisor.
Use the rmon alarm command to create a new RMON alarm entry.
The syntax for this command is:
rmon alarm <Alarm Number> <variable> <interval> <sample type>
rising-threshold <rising threshold> <rising event> falling-
threshold <falling threshold> <falling event> <startup alarm>
<owner>
Example:
Alarm Number This is the alarm index number of this entry (it is advisable to
use the same interface number as your alarm index number.)
variable The instance of an RMON statistic.
interval The interval between 2 samples.
sample type This can be set to either delta (the difference between 2
samples) or an absolute value.
rising threshold This sets the upper threshold for the alarm entry.
rising event The RMON event entry that will be notified if the upper
threshold is passed.
falling
threshold
This sets the lower threshold for the alarm entry.
falling event The RMON event entry that will be notified if the lower
threshold is passed.
startup alarm The instances in which the alarm will be activated. The
possible parameters are: Rising, Falling, risingOrfalling.
owner Owner name string.
P330-N# rmon alarm 1026 1.3.6.1.2.1.16.1.1.1.5.1026 60
delta rising-threshold 10000 1054 falling-threshold 10 1054
risingOrFalling gregory
alarm 1026 was created successfully