Cisco Systems MGX 8220 Switch User Manual


 
5-15
Cisco MGX 8220 Installation and Configuration
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Chapter
Configuring IMATM Connections
Checking the Alarms on a ds1 Line
On the sample display shown above, line number 1, 2, 3, 4 are out of alarm. Lines 5, 6, 7, 8 are in alarm.
Enter the following command on the command line at IMATM prompt to check the alarm on ds1 line#6:
AXIS18.1.9.IMATM.a > dspalm -ds1 6
Sample Display
AXIS18.1.9.IMATM.a > dspalm "-ds1 6"
dspalm "-ds1 6"
LineNum: 6
LineAlarmState: Alarm(s) On --
RcvLOS
LineStatisticalAlarmState: No Statistical Alarms
To check the Out of Frames, the number of RAIs and so on, enter the following command on the
command line:
AXIS18.1.9.IMATM.a > dspalmcnt -ds1 1
Sample Display
Line RcvLOSCount RcvOOFCount RcvRAICount RcvFECount
---- ----------- ----------- ----------- ----------
9.1 0 1 0 2
Always clear up all the alarms before checking up for dspalmcnt. To clear up all the alarms enter the
following command on the command line:
AXIS18.1.9.IMATM.a > clralmcnt -ds1 1 1
dspaimlncnt "AIM_GRP_NO LINE_NO"
This command will display any HEC errored cell received on a particular line (which is part of the AIM
group).
Clearing Any Alarms Related to ds3
Make sure the ds3 is out of alarm. There should not be any alarms. To display the ds3 alarms, enter the
following command on the command line:
AXIS18.1.9.IMATM.a > dspalm -ds3 1