Cisco Systems MGX 8220 Switch User Manual


 
6-5
Cisco MGX 8220 Installation and Configuration
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Chapter
Provisioning FRSM Channels
Provisioning FRSM Channels
To provision a FRSM channel in a stand-alone application:
1. Enter the cc command to change the active CLI card to the slot number corresponding to the
channel to be provisioned. For example,
myshelf.1.3.ASC. a >
cc 5
2. Enter the addln command to add a physical line (line number corresponds to the physical line
module port number for the channel being provisioned). Then enter the dsplns command to verify
the line has been added. For example,
myshelf.1.5.FRSM. a >
addln
myself.1.5.FRSM. a >
dsplns
3. Enter the addport command to add a Frame Relay port to the enabled line. Then enter the dspports
command to verify the port has been added. For example,
myshelf.1.5.FRSM. a >
addport
myself.1.5.FRSM. a >
dspports
4. Enter the addchan command to add a Frame Relay endpoint. Then enter the dspchans command
to verify the channel has been added. For example,
myshelf.1.5.FRSM.a>a
ddchan
myself.1.5.FRSM.a>
dspchans
Provisioning AUSM Channels
To provision a AUSM channel in a stand-alone application
1. Enter the cc command to change the active CLI card to the slot number corresponding to the
channel to be provisioned. For example,
myshelf.1.3.ASC. a >
cc 5
2. Enter the addln command to add a physical line (line number corresponds to the physical line
module port number for the channel being provisioned). Then enter the dsplns command to verify
the line has been added. For example,
myshelf.1.5.AUSM. a >
addln (add line parameters)
myself.1.5.AUSM. a >
dsplns
3. Enter the addport command to add a ATM port to the enabled line. Then enter the dspports
command to verify that the port has been added. For example,
myshelf.1.5.AUSM. a >
addport
myself.1.5.AUSM. a >
dspports