Cisco Systems MGX 8220 Switch User Manual


 
C-15
Cisco MGX 8220 Installation and Configuration
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Appendix C Firmware Upgrade and Downgrade Procedures
Standard Upgrade and Downgrade Procedures
c. Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This step downloads new firmware into the ASC.
d. Enter the switchcc command to switch to the other ASC.
e. Enter the tftp put <ASC_BT_file> AXIS_ASC_BACKUP.FW command. This step downloads the
new boot code into the second ASC.
f. Enter the chkflash command. This command calculates and compares the Flash checksum to verify
whether the boot code is correct.
g. Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This step downloads new firmware into the ASC.
h. Enter the tftp put <ASC_FW_file> AXIS_ASC_ACTIVE.FW command.
i. Check the file size of the downloaded firmware. Use this step to check that the firmware was
downloaded successfully to the ASC disk.
j. Enter the dspfwrevs command to verify the correct firmware revision.
k. Enter the tftp put <ASC_FW_file> AXIS_ASC_STANDBY.FW command.
l. Check the file size of the downloaded firmware. Use this step to check that the firmware was
downloaded successfully to the ASC disk.
m. Enter the dspfwrevs command to verify the correct firmware revision.
Step 4 For all SM
a. Enter the tftp put <SM_BT_file> AXIS_SM_!$slot.BOOT command.
b. Enter the chkflash command. This command calculates and compares the Flash checksum to verify
whether the boot code is correct.
c. Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This step downloads new firmware into the ASC.
Step 5 For all SMs, set the start and end addresses in Flash memory where the boot code file is written.
a. Enter the flashStartAddr and flashEndAddr commands to start the Flash memory file at
Oxbfc40000 and end it at 0xbfd00000
shelf.1.<slot>.<type><a|s>flashStartAddr = 0xbfc40000
shelf.1.<slot>.<type>.<a|s>flashEndAddr = 0xbfd00000
b. Enter the tftp put <SM_FW_file> AXIS_SM_1_$slot.BOOT command.
c. Enter the chkflash command. This command calculates and compares the Flash checksum to verify
whether the boot code is correct.
d. Enter the clrallcnf command. This command resets all cards on the shelf.
Step 6 For all SMs, enter the dsptotals command.
Use this step to examine the number of lines, ports, and channels after the upgrade or downgrade. The
values can be compared to those before the download and, therefore, it can be established that the
configuration has remained the same. Restore the ASC and SM configurations if necessary.