Cisco Systems (VISM) Network Card User Manual


 
6-8
Cisco VISM Installation and Configuration Guide
Release 3.0, Part Number OL-2521-01 Rev. D0, June 2004
Chapter 6 Troubleshooting Tips
Symptoms and Solutions
1.4 Empty Clear
1.5 Failed VISM-8E1 Clear
1.6 Empty Clear
1.7 Active PXM1-OC3 Clear
1.8 Empty Clear
1.9 Empty Clear
1.10 Empty Clear
1.11 Empty Clear
1.12 Empty Clear
1.13 Empty Clear
1.14 Empty Clear
1.15 Empty Clear
1.16 Empty Clear
1.17 Empty Clear
1.18 Empty Clear
1.19 Empty Clear
VISM Front Card/Back Card Mismatch
Use the following PXM dsplog command to investigate a possible VISM front card/back card mismatch:
NODENAME.1.7.PXM.a > dsplog
01/01/2001-00:02:24 05 cmm VISM-6-9025
VISM going to standby : Config. Mismatch between ASC and VISMV
01/01/2001-00:02:24 05 cmm VISM-6-9023
Mismatch Backcard
01/01/2001-00:02:24 05 cmm VISM-6-9023
Mismatch Backcard
In a mismatch condition, use the PXM dspcds command to display the following type of information:
NODENAME.1.7.PXM.a > dspcds
Slot CardState CardType CardAlarm Redundancy
---- ----------- -------- --------- -----------
1.1 Empty Clear
1.2 Empty Clear
1.3 Empty Clear
1.4 Empty Clear
1.5 Mismatch VISM-8E1 Clear
1.6 Empty Clear
1.7 Active PXM1-OC3 Clear
1.8 Empty Clear
1.9 Empty Clear
1.10 Empty Clear
1.11 Empty Clear
1.12 Empty Clear
1.13 Empty Clear
1.14 Empty Clear
1.15 Empty Clear
1.16 Empty Clear
1.17 Empty Clear
1.18 Empty Clear
1.19 Empty Clear
Use the VISM dspcd command to display the following types of information:
NODENAME.1.5.VISM8.s > dspcd
ModuleSlotNumber: 5
FunctionModuleState: Mismatch
FunctionModuleType: VISM-8E1
FunctionModuleSerialNum: CAB0246014P
FunctionModuleHWRev: 0.0