SATO M-5900RV Operator and Technical Reference Manual
Page 4-43
Section 4. Programming Reference
PN 9001081
Rev. C
Form Overlay, Recall
Command Structure
<ESC>/
Example: See above
Placement: Must be preceded by all other data and placed just before the Print
Quantity command (<ESC>Q).
Default: None
Command Function
To recall the label image from the form overlay memory for printing. This command
recalls a stored image from the overlay memory. Additional or different data can be
printed with the recalled image.
Printer Input
<ESC>A
<ESC>H0001<ESC>V0125
<ESC>STHIS IS THE STORED IMAGE WITH A BARCODE
<ESC>H0001<ESC>V0165<ESC>B103100*12345*
<ESC>&<ESC>Z
<ESC>A<ESC>H0001<ESC>V0050
<ESC>STHIS IS RECALLING AND ADDING TO THE STORED IMAGE<ESC>/
<ESC>Q1<ESC>Z
Printer Output
1. The overlay is stored using the <ESC>& Form Overlay Store command
(see Page 4-44).
2. If this command is used with the <ESC>AX Expanded Print Length command (see
Page 4-59) the Form Overlay length cannot exceed 14".
Special Notes