SATO M-5900RV Operator and Technical Reference Manual
Page 4-79
Section 4. Programming Reference
PN 9001081
Rev. C
Calendar Print
This command requires the Calendar option.
Command Structure
<ESC>WA(elements)
(elements) = YYYY 4 digit Year (1981-2080)
YY 2 digit Year (00-91)
MM Month (01-12)
DD Day (01-31)
HH 12 Hour Clock (00-11)
hh 24 Hour Clock (00-23)
mm Minute (00-59)
ss Seconds (00-59)
TT AM or PM
JJJ Julian Date (001-366)
WW Week (00-53)
ww Week (01-54)
Example: <ESC>WAMM/DD/YY
Placement: Anywhere within the data stream
Default: None
Command Function
To Specify the printing of a date and/or time field from the printer's
internal clock. This may be used to date/time stamp your labels.
Printer Input
<ESC>A
<ESC>H0100<ESC>V100<ESC>XB1The current date is:
<ESC>XB1<ESC>WAMM/DD/YY
<ESC> WPM06
<ESC>H0100<ESC>V0200<ESC>XB1The current time is:
<ESC>XB1<ESC>WAhh:mm
<ESC> Q1<ESC>Z
Printer Output