Memory Card Function
Graphics, PCX Recall
Command Structure
<ESC>PYaaa
aa = Storage area number (001 thru 099)
Example: <ESC>PY001
Placement: This command must be placed within its own data stream specifying the
placement of the graphic.
Default: None
Command Function
To recall for printing a graphic file previously stored in a PCX format in the Memory Card.
Printer Input
Printer Output
Special Notes
1. This command requires the Memory Card option. See your SATO representative for
details.
2. See the <ESC>PI Store PCX Graphics command.
Normal Rotation Rotate Base Reference Point
<ESC>A<ESC>CC1 <ESC>A<ESC>CC1<ESC>%1
<ESC>V0100<ESC>H0000<ESC>PY001 <ESC>V0330<ESC>H0180<ESC>PY001
<ESC>Q1<ESC>Z <ESC>Q1<ESC>Z
2nd Rotation, Base Reference Point 3rd Rotation, Base Reference Point
<ESC>A<ESC>CC1<ESC>%2 <ESC>A<ESC>CC1<ESC>%3
<ESC>V0330<ESC>H0600<ESC>PY001 <ESC>V0100<ESC>H0800<ESC>PY001
<ESC>Q1<ESC>Z <ESC>Q1<ESC>Z
This command requires the Memory Card option.