SATO M-5900RV Operator and Technical Reference Manual
Page 4-65
Section 4. Programming Reference
PN 9001081
Rev. C
Repeat Label
Command Structure
<ESC>C
Example: See above
Placement: Must be placed immediately after <ESC>A and immediately
before <ESC>Z in its own separate data stream.
Default: None
Command Function
To print duplicate of the last label printed
Printer Input
<ESC>A
<ESC>C
<ESC>Z
Printer Output
A duplicate of the previous label will be printed.
Special Notes
This command will have no effect if the power to the printer was cycled off
and back on since printing the previous label.