Section 4. Programming Reference
PN 9001081
Rev. C
Custom Protocol Command Codes
Download
Special Notes
1. Commas must be used to separate the parameters. If a parameter is omitted
between two commas, the default Non-Standard Protocol Command codes for
that parameter will be used. See Appendix E.
2. This command must be sent as an independent data stream immediately
following the <ESC>A Start code and immediately preceding the <ESC>Z Stop
code. No other commands can be included in the data stream.
3. If more or less than nine commas are included in the command, the entire
command sequence will be ignored. The command must contain exactly nine
commas.
4. If two characters are specified for a parameter, it will be interpreted as a hex
value. For example:
Command Parameter Resulting Command Code
2B +
++
If a combination of characters are outside the hexadecimal range, the entire
command sequence will be ignored.
5. Downloading Auto Online and Zero Slash settings will overwrite the values
selected using the LCD panel. If these settings are changed using the LCD
panel, they will overwrite any previously downloaded settings.
Printer Output (Cont)
STX = 7B ETX = 7D ESC = 25
ENQ = 23 CAN = 26 NULL = 2A
OFFLINE = 7E
AUTO ONLINE = YES
ZERO SLASH = YES
Press the "FEED" key to activate
the User Default or power the
printer off to ignore them.