SATO M-5900RV Operator and Technical Reference Manual
Page B-3
Appendix B. Bar Code Specifications
PN 9001081
Rev. C
Code 39
Command Structure
1:3 ratio <ESC>Blbbccc* (data) *
2:5 ratio <ESC>BD1bbccc*(data) *
1:2 ratio <ESC>D1bbccc* (data) *
bb = Width of narrow element in dots (01-12)
ccc = Bar height in dots (001-600)
* = Required Start and Stop character (A, B, C, or D)
(data) = Bar code data (alphanumeric)
Character Set
0-9, A-Z, Space, $,%,+,-,.,/
* (Start/Stop characters)
Density Table
Example
<ESC>H0100<ESC>V0025<ESC>B103100*CODE 39*
<ESC>H0230<ESC>V0130<ESC>XS*CODE 39*
Notes
You must add the "*"Start and Stop characters to the data string. The
printer does not automatically add them when printing.
ediW/worraN
oitaR
eulaV
"bb"fo
"X"
noisnemiD
)slim(
ytisneD
)hcni/rahc(
3:1100.57.21
3:1200.014.6
5:2100.010.7
2:1100.56.51
2:1200.018.7