SATO M-5900RV Operator and Technical Reference Manual
Page B-20
Appendix B. Bar Code Specifications
PN 9001081
Rev. C
Maxicode
Command Structure
<ESC>BVa,b,c,ddddddddd,eee,fff,gggg....<ESC>
a = Position of Maxicode symbol within the set, when used in
a structured append format 1-8
b = Total number of Maxicode symbols in the set, when used
in a structured format 1~8.
c = 2 For Mode 2 Structured Carrier Message for Domestic
U.S. UPS shipments
3 For Mode 3 Structured
Carrier Message for International UPS shipments
4 Standard symbol
5 Not currently supported
6 Reader programming
ddd..ddd 9 digit numeric Postal Code
eee = 3 digit numeric County Code
fff = 3 digit numeric Service Code
gg..g = Data, terminated by <ESC>
Character Set
EDOM
LATSOP
EDOC
YRTNUOC
EDOC
ECIVRES
SSALC
EGASSEM
HTGNEL
2
xamstigid9
ylnociremun
xamstigid3
ylnociremun
xamstigid3
ylnociremun
sretcarahc48
ciremunahpla
3
dexifstigid6
ciremunahpla
xamstigid3
ylnociremun
xamstigid3
ylnociremun
sretcarahc48
ciremunahpla
4
6
"000000"
ataddexif
"000"
ataddexif
"000"
ataddexif
sretcarahc19
ciremunahpla
Example
<ESC>A<ESC>V0100<ESC>H0100
<ESC>BV1,1,2,123456789,840,001,[)<RS>01<GS>961Z01547089
<GS>UPSN<GS>056872<GS>349<GS>99999999<GS>001/005
<GS>029<GS>N<GS><GS>LENEXA<GS>KS<RS><EOT>
<ESC>Q001<ESC>Z
Notes
See AIM USA Technical Specification Data Matrix for information on
the structure of this symbology.