Cuda 12000 IP Access Switch CLI-based Administration Guide
Assertion Levels 151
Configuring the Power Assertion Level
You must verify the assertion level specified by the power supply vendor to
indicate fault conditions, and set the assertion levels as specified by the
vendor.
To configure the assertion level that the power supply utilizes when
indicating a fault condition, perform the following tasks:
To display the assertion levels currently configured for both AC and DC and
power supply temperature fault indications, perform the following tasks:
Task Command
1. Enter root mode. root
2. Set the assertion level to report
AC current faults.
aux-device ac-monitor fault-level
{active-high | active-low}
3. Set the assertion level to report
DC current faults.
aux-device dc-monitor fault-level
{active-high | active-low}
4. Set the assertion level to report
power supply temperature
faults.
aux-device ps-temp fault-level
{active-high | active-low}
Task Command
1. Enter root mode. root
2. Display the assertion level
currently configured for the
reporting of AC current faults.
show aux-device ac-monitor
3. Display the assertion level
currently configured for the
reporting of DC current faults.
show aux-device dc-monitor
4. Display the assertion level
currently configured for the
reporting of power supply
temperature faults.
show aux-device ps-temp