Cuda 12000 IP Access Switch CLI-based Administration Guide
Configuring the Downstream Channel 389
Example
The following example shows a downstream channel configuration.
cli:172.16.19.10:root# show topology | include docs
1 / 1 / 1 Egress docsCableMaclayer Active
1 / 6 / 1 Egress docsCableMaclayer Active
cli:172.16.19.10:root# interface 1/1/1
mode: interface:cable:csi(1/1/1)
cli:172.16.19.10:interface:cable:csi(1/1/1)# downstream no shutdown
cli:172.16.19.10:interface:cable:csi(1/1/1)# downstream frequency 700
cli:172.16.19.10:interface:cable:csi(1/1/1)# downstream interleave-depth 32
cli:172.16.19.10:interface:cable:csi(1/1/1)# downstream modulation qam256
cli:172.16.19.10:interface:cable:csi(1/1/1)# downstream transmit-power 500
cli:172.16.19.10:interface:cable:csi(1/1/1)# show downstream
C/S/P 1 / 1 / 2 / 2
Frequency 700.0 (MHz)
Interleave taps32Increment4
Modulation qam256
ChannelWidth 6 (MHz)
ChannelPower 500 (1/10 dBmV)
AnnexType Annex B
Symbol Rate 5360537 (baud)
Admin Status up
Operational Status up
Out Octets 678884867
Out Unicast Packets 15578
Out Multicacast Packets 15252214
Out Broadcast Packets 312
Out Errors 0
Out Discards 0
cli:172.16.19.10:interface:cable:csi(1/1/1)#