ADC 3 Switch User Manual


 
ADC Telecommunications, Inc.
156 C
HAPTER 8: TIMING AND ALARM CONTROLLER MANAGEMENT
Viewing Fault Reporting Status
Each fault condition displays one of the following states.
disabled — Reporting is not specified for the fault condition. An SNMP
Trap or syslog message is not generated when the fault condition occurs.
faulted — Fault reporting is specified. An SNMP trap or syslog message is
generated when the fault condition occurs.
okay — Fault reporting is specified.
Use the
show chassis-fault status command to display the state of each
fault condition.
Example
The following example displays that faults are to be reported for the
backplane power and local power-source-a conditions. In addition, the
display indicates that faults have not occurred for the specified conditions.
cli:192.168.244.212:root# chassis-fault backplane-power
local-pwr-a
cli:192.168.244.212:root# show chassis-fault status
Chassis Fault Status
Bits A Fault disabled
Bits B Fault disabled
Backplane System Fault disabled
Backplane Temp Fault disabled
Backplane Power Fault okay
Backplane Power A Fault disabled
Backplane Power B Fault disabled
Red Alarm Fault disabled
Blue Alarm Fault disabled
Yellow Alarm Fault disabled
Processor Temp Fault disabled
Ps Temp Fault disabled
Ps AC Fault disabled
Ps DC Fault disabled
Fan Temp Fault disabled
Fan Rotation Fault disabled
Local Pwr A Fault okay
Local Pwr B Fault disabled