ADC 3 Switch User Manual


 
Cuda 12000 IP Access Switch CLI-based Administration Guide
Configuring SNMP Event Notification Types 189
Level The level of security to process SNMP
messages. You can choose one of the
following three levels:
No Authentication: Provides no
authentication and no encryption.
This is the lowest level of security.
V1 and V2c security models provide
only this level of security.
Authentication: Provides
authentication but no encryption.
Only V3 security model provides
this level of security.
Privacy: Provides authentication
and encryption. This is the highest
level of security. Only V3 security
model provides this level of
security.
Group Name The community name associated to
the SNMP group for the specific SNMP
host.
Type Indicates whether the notification is
sent as a trap or inform.
Notifications Sent The type of event for which you want
to be notified. Notifications may be
specified for system events occurring
for clusters, modules, interfaces and
DOCSIS modules.
Cluster events: Cluster events refer to faults that
affect the management module.
authentication-failure SNMP receives a bad Community
Name.
bcm-failover-down Services are going down. This
notification type applies to redundant
configurations only.
bcm-failover-up Services are coming up. This
notification type applies to redundant
configurations only.
bcm-state-change A change in the craft port IP address.
Parameter Description