ADC Telecommunications, Inc.
184 C
HAPTER 9: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
■ Interface-related events: Interface-related events refer to faults that
affect the link state of the interface.
Notice
■ link up Link to IP network is operational. Notice
■ link down Link to IP network is not operational. Error
■ chassis-fault Auxiliary device-related event that refers to
faults associated to the fan tray, power
source and clock sources.
NOTE: Reference “Timing and Alarm
Module Fault Reporting” on page 155, for
a list of the chassis-related notification
types.
Critical
■ chassis-fault-cleared Indicates the chassis event that caused a
fault is fixed.
Notice
Provisioning events: Provisioning events refer to faults that
pertain to the FastFlow BPM running on
the Cuda 12000.
■ duplicate-addr A duplicate IP address has been detected. Notice
■ isp-addr-high The free IP address count exceeded the
upper threshold for the specified ISP.
Notice
■ isp-addr-low The free address count fell below the
lower threshold for the specified ISP.
Notice
■ ldap-failed A directory server access failure occurred. Notice
■ ldap-restored Directory server access is operational after
a failure.
Notice
■ prov-service A FastFlow BPM service started, stopped,
or failed.
Notice
■ subnet-addr-high The free IP address count exceeded the
high available address threshold for a
subnet.
Notice
■ subnet-addr-low The free IP address count fell below the
low available address threshold for a
subnet.
Notice
DOCSIS events: DOCSIS events refer to initialization faults
on DOCSIS and EuroDOCSIS modules.
■ docs-dyn-rsp-fail A dynamic service response failure
occurred during the dynamic services
process.
Warning
System Event Description Event Class