ADC 3 Switch User Manual


 
ADC Telecommunications, Inc.
184 C
HAPTER 9: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
Interface-related events: Interface-related events refer to faults that
affect the link state of the interface.
Notice
link up Link to IP network is operational. Notice
link down Link to IP network is not operational. Error
chassis-fault Auxiliary device-related event that refers to
faults associated to the fan tray, power
source and clock sources.
NOTE: Reference “Timing and Alarm
Module Fault Reporting” on page 155, for
a list of the chassis-related notification
types.
Critical
chassis-fault-cleared Indicates the chassis event that caused a
fault is fixed.
Notice
Provisioning events: Provisioning events refer to faults that
pertain to the FastFlow BPM running on
the Cuda 12000.
duplicate-addr A duplicate IP address has been detected. Notice
isp-addr-high The free IP address count exceeded the
upper threshold for the specified ISP.
Notice
isp-addr-low The free address count fell below the
lower threshold for the specified ISP.
Notice
ldap-failed A directory server access failure occurred. Notice
ldap-restored Directory server access is operational after
a failure.
Notice
prov-service A FastFlow BPM service started, stopped,
or failed.
Notice
subnet-addr-high The free IP address count exceeded the
high available address threshold for a
subnet.
Notice
subnet-addr-low The free IP address count fell below the
low available address threshold for a
subnet.
Notice
DOCSIS events: DOCSIS events refer to initialization faults
on DOCSIS and EuroDOCSIS modules.
docs-dyn-rsp-fail A dynamic service response failure
occurred during the dynamic services
process.
Warning
System Event Description Event Class