550 C
HAPTER 21: MIB BROWSING
Table 21-17 docsDevEvControlTable Parameters (Configuration)
.
CLI Output Description
Syslog Server IP address of the Syslog server. If the value is 0.0.0.0,
the syslog transmission is inhibited.
Threshold Number of trap/syslog events per Throttle Interval to
transmit before throttling.
Interval (seconds) Interval over which the trap threshold applies. At initial
startup, this value is one.
Admin Status
The options are:
Controls the transmission of traps and syslog messages
with respect to the trap pacing threshold. A single
event is counted as a single event for threshold
counting. That is, an event causing both a trap and a
syslog message is still considered a single event.
unconstrained Causes traps and syslog messages to transmit without
regard for threshold settings. At initial startup, this is
the default.
maintainBelowT
hreshold
Causes the suppression of trap transmission and syslog
messages if the number of traps would otherwise
exceed the threshold.
stopAtThreshold Causes trap transmission to cease at the threshold, and
not resume until you manually intervene.
inhibited Causes the suppression of all trap transmission and
syslog messages.
Inhibited Indicates whether the trap and syslog transmission is
inhibited because of thresholds or the current settings