ADC 3 Switch User Manual


 
Cuda 12000 IP Access Switch CLI-based Administration Guide
Configuring SNMP Event Notification Types 191
chassis-fault-cleared Indicates the chassis event that caused
a fault is fixed.
DOCSIS events: DOCSIS events refer to initialization
faults on DOCSIS and EuroDOCSIS
modules.
docs-dyn-rsp-fail A dynamic service response failure
occurred during the dynamic services
process.
docss-dyn-ack-fail A dynamic service acknowledgement
failure occurred during the dynamic
services process.
docs-dyn-req-fail A dynamic service request failure
occurred during the dynamic services
process.
docs-bpi-init A BPI initialization attempt failure
occurred during the registration
process.
docs-bpkm A baseline privacy key management
operation failed.
docs-dcc-ack-fail A dynamic channel change
acknowledgement failed during the
dynamic channel change process in
the CMTS.
docs-dcc-req-fail A dynamic channel change request
failed during the dynamic channel
change process in the cable modem
and was detected by the CMTS.
docs-dcc-rsp-fail A dynamic channel change response
failed during the dynamic channel
change process in the CMTS.
docs-dynamic-sa A dynamic security association failed.
docs-init-ack-fail A registration acknowledgement
failure from the cable modem
occurred during the cable modem
initialization process and was detected
on the CMTS side.
docs-init-req-fail A registration request failure from the
cable modem occurred during the
cable modem initialization process and
was detected on the CMTS side.
Parameter Description