ADC 3 Switch User Manual


 
Cuda 12000 IP Access Switch CLI-based Administration Guide
Configuring Alarms Out 159
Task Command
1. Enter root mode. root
2. Specify the types of alarm
signals that you want to
enable, to set the fault to send
alarm signals out the DB-15
connector.
no aux-device db15 alarm
{blue |
clock [bits-a] [bits-b] [red-alarm] |
power-alarm [backplane-power]
[backplane-pwr-a]
[backplane-pwr-b]
[local-pwr-a] [local-pwr-b] [ps-ac]
[ps-dc] |
power-fail-A |
power-fail-B |
red [bits-a] [bits-b] [red-alarm] |
system [backplane]
[backplane-power]
[backplane-temp] [fan-rotation]
[fan-temp] [local-pwr-a]
[local-pwr-b] [ps-ac] [ps-dc]
[ps-temp] [red-alarm] |
temp [backplane-temp] [fan-temp]
[processor-temp] [ps-temp] |
yellow}
3. Specify the types of alarm
signals that you want to
disable, to prohibit the faults
from being sent out the DB-15
connector.
aux-device db15 alarm
{blue |
clock [bits-a] [bits-b] [red-alarm] |
power-alarm [backplane-power]
[backplane-pwr-a]
[backplane-pwr-b]
[local-pwr-a] [local-pwr-b] [ps-ac]
[ps-dc] |
power-fail-A |
power-fail-B |
red [bits-a] [bits-b] [red-alarm] |
system [backplane]
[backplane-power]
[backplane-temp] [fan-rotation]
[fan-temp] [local-pwr-a]
[local-pwr-b] [ps-ac] [ps-dc]
[ps-temp] [red-alarm] |
temp [backplane-temp] [fan-temp]
[processor-temp] [ps-temp] |
yellow}