Configuring SNMP Event Notification Types 183
The following table lists the system events and their associated Event
Classes. For more information about Event Classes, refer to Chapter 10,
Managing System Events, on page 203.
Table 9-7 List of System Events
E
System Event Description Event Class
Cluster events: Cluster events refer to faults that affect
the management module.
authentication-failure SNMP receives a bad Community Name. Notice
bcm-failover-down Services are going down. This notification
type applies to redundant configurations
only.
Notice
bcm-failover-up Services are coming up. This notification
type applies to redundant configurations
only.
Notice
bcm-state-change A change in the craft port IP address. Notice
bcm-sw-mismatch The secondary will not come up because
its software revision does not match the
software revision of the primary.
Notice
trace-log For ADC internal use only. Notice
cold-start Generated when module boots from
power up.
Notice
warm-start Generated when module boots from reset. Notice
icl-state-change A change in the ICL link. Notice
Module events: Module events refer to hardware faults
that affect any application module.
cable-modem-auth-failure Cable modem failed authorization and did
not register.
Notice
cable-modem-down Cable modem is not operational. Critical
cable-modem-up Cable modem is operational. Notice
card-down Application module failure. Critical
card-up Application module is operational. Notice
dhcp-relay-not-configured DHCP configuration error. Warning
local-sonet-alarm A transmission problem is detected from
the transmitter.
Error
remote-sonet-alarm A transmission problem is detected from
the receiver.
Error