HAPTER 9: SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
Configuring System Name, Contact, and Location
For the Cuda 12000, you can configure system name, contact, and location
information. This information is stored in the sysName, sysContact, and
sysLocation MIB variables. This information is described as follows:
Table 9-6 System Name, Contact, and Location Parameters
Perform the following tasks to configure name, contact, and location
information for the Cuda 12000:
A name, contact, or location text string may
contain up to 255 alphanumeric
characters.
If a text string contains spaces, you may enclose the string in
quotes.
Parameter Description
Name The name of the system (sysName MIB object).
Contact The type of contact for this network (sysContact MIB
object). The contact is typically a network
administrator’s name, extension, and/or e-mail address.
Location The physical location of the Cuda 12000 (sysLocation
MIB object).
Task Command
1. Enter configuration mode. root
2. Specify the SNMP contact. snmp-server contact <contact>
3. Specify the system’s name. snmp-server name <name>
4. Specify the system’s physical
location.
snmp-server location <location>
5. Display the contact, name and
location information.
show snmp
6. Remove the contact, name or
location information.
no snmp-server {contact | name |
location}