HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
edge switch 2/16 service manual 2–61
Diagnostics
6
Does the embedded web server interface appear operational?
YES NO
Analysis for an Ethernet link, AC power distribution, or CTP card failure is not
described in this MAP. Go to "
MAP 0000: Start MAP
" on page 2-7. If this is the
second time at this step, contact the next level of support.
7
Inspect the fan operational states at the embedded web server interface.
a. At the View panel, click the Component Properties tab. The View panel
(Component Properties tab) displays.
b. Inspect the State fields for Fan 0 through Fan 3.
Does the State field display a Failed message for any fan?
YES NO
The switch appears operational.
8
A fan failed or is improperly installed.
a. Partially remove a fan from the chassis.
b. Reseat the fan in the chassis.
Does the fan appear to function?
NO YES
The switch appears operational.
9
A fan failed and must be removed and replaced ("RRP: Cooling Fan" on page 4-6.
Does the fan appear to function?
NO YES
The switch appears operational.
Contact the next level of support.