HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
2–80 edge switch 2/16 service manual
Diagnostics
2
The following table lists event codes, brief explanations of the codes, and associated
steps that describe fault isolation procedures.
3
Is fault isolation being performed at the HAFM server?
YES NO
Fault isolation is being performed through the embedded web server
interface. Go to step 17.
4
Does a yellow triangle (attention indicator) appear to overlay the port graphic at the
Hardware View?
YES NO
The problem is transient and the switch-to-fabric device connection appears
operational.
5
Inspect the port state and LED status for the port.
Event
Code Explanation Action
011 Login server database invalid. Go to step 7.
021 Name server database invalid. Go to step 7.
051 Management server database invalid. Go to step 7.
052 Management server internal error. Go to step 7.
061 Fabric controller database invalid. Go to step 7.
062 Maximum interswitch hop count
exceeded.
Go to step 8.
070 E_Port is segmented. Go to step 9.
071 Switch is isolated. Go to step 9.
072 E_Port connected to an unsupported
switch.
Go to step 10.