B–22 edge switch 2/16 service manual
Event Codes
CTP2 Card Events (400 through 499)
NOTE: The term CTP card refers to the main circuit board of the Edge Switch 2/16, not to a
separate card that contains the CTP. The CTP is an integral part of the main circuit board.
Event Code: 400
Message: Power-up diagnostics failure.
Severity: Major.
Explanatio
n:
Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as indicated
by the event data.
Action: Replace the failed FRU with a functional FRU. Perform the data collection procedure
and return the Zip disk and faulty FRU to Hewlett Packard support personnel.
Event
Data:
Byte 0 = FRU code as follows: 01 = backplane, 02 = CTP2 card, 03 = SBAR, 05 = fan
module, 06 = power supply, and 08 through 0F = UPM cards.
Byte 1 = FRU slot number.
Distributio
n:
Switch HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call-Hom
e
Sense
Info
Link
Incident
444444
Event Code: 410
Message: CTP card reset.
Severity: Informational.
Explanatio
n:
The CTP card reset after a switch power-on, hardware IML, or software IPL. An IPL can
be user-initiated at the switch- Product Manager application, or occur automatically after
a firmware fault (event code 411). The event data indicates the type of reset.
Action: No action required.
Event
Data:
Byte 0 = reset type as follows: 00 = power-on or single CTP2 card hot-insert, 02 = IML,
04 = IPL,
08 = reset by other CTP2 card, 40 = partition switch, or 80 = dual CTP2 card hot-insert.