HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
edge switch 2/16 service manual A–21
Messages
Cannot run
diagnostics on a port
that is failed.
Port diagnostics
(loopback tests)
cannot be performed
on a port that has
failed any previous
diagnostic (power-on
diagnostic, online
diagnostic, or
loopback test). The
amber LED
associated with the
port illuminates to
indicate the failed
state.
Reset the port and perform
diagnostics again.
Cannot run
diagnostics on a port
that is not installed.
Port diagnostics
(loopback tests)
cannot be performed
on a port that does
not have a small form
factor pluggable
(SFP) optical
transceiver installed.
Install a transceiver in the port
and perform diagnostics
again.
Cannot run
diagnostics while a
device is logged-in to
the port.
Port diagnostics
(internal loopback
test) cannot be
performed on a port
while an attached
Fibre Channel device
is logged in.
Ensure the device is logged
out and perform diagnostics
again.
Cannot save port
configuration.
The port
configuration cannot
be saved at the
product manager
application because
the Ethernet link is
down or busy.
Retry the operation later. If
the condition persists, contact
the next level of support.
Message Description Action