HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
edge switch 2/16 service manual B–9
Event Codes
Event Code: 071 (continued)
Event
Data
(continued
):
4 = Build fabric protocol error. A protocol error was detected during incorporation of
the switch into the fabric. Disconnect the E_Port link, reconnect the link, and IPL the
switch. If the condition persists, perform the data collection procedure and return the Zip
disk to Hewlett Packard support personnel.
5 = No principal switch. No director or switch in the fabric can become the principal
switch. Modify the switch priority to any value other than 255.
6 = No response from attached switch (hello timeout). The switch periodically
verifies operation of attached fabric elements (directors or switches). The switch E_Port
(at the operational switch) times out and segments if the attached device does not
respond. Check the status of the attached director or switch. If the condition persists,
perform the data collection procedure (at the attached device) and return the Zip disk to
Hewlett Packard support personnel.
7 = ELP retransmission failure timeout. A switch that exhibits a hardware or link
failure attempted to join a fabric and transmitted multiple ELP frames to a fabric element
(director or switch). However, because of the problem, the switch did not receive
responses to the ELP frames, and did not receive an FLOGI frame. After five ELP
transmission attempts, the switch E_Port (failed switch) times out and segments. Refer
to MAP 0000: Start MAP to perform hardware fault isolation at the failed switch.
Distributio
n:
Switch HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call-Hom
e
Sense
Info
Link
Incident
44
Event Code: 072
Message: E_Port connected to unsupported switch.
Severity: Informational.
Explanatio
n:
The switch is attached (through an ISL) to an incompatible fabric element (director or
switch).
Action: Disconnect the ISL.
Event
Data:
No supplementary data included with this event.