edge switch 2/16 service manual 2–83
Diagnostics
c. Byte 0 specifies the port number (00 through 15) of the segmented E_port. Byte
4 specifies the segmentation reason as listed in the following table.
10
As indicated by an event code 072, the switch E_Port is connected to an unsupported
switch.
Advise the customer of the problem and disconnect the interswitch link to the
unsupported switch.
11
The switch E_Port segmented because the error detect time-out value (E_D_TOV) or
resource allocation time-out value (R_A_TOV) is incompatible with the attached fabric
element.
a. Contact Hewlett Packard customer support or engineering personnel to
determine the recommended E_D_TOV and R_A_TOV values for the switches.
b. Notify the customer that both switches will be set offline. Ensure the system
administrator stops Fibre Channel frame traffic through the switches and sets
attached devices offline.
c. Set both switches offline ("
Set Offline State
" on page 3-38).
Byte
3 Segmentation Reason Action
01 Incompatible operating
parameters.
Go to step 11.
02 Duplicate domain IDs. Go to step 12.
03 Incompatible zoning
configurations.
Go to step 13.
04 Build fabric protocol error. Go to step 14.
05 No principal switch. Go to step 19.
06 No response from attached
switch (Hello Timeout).
Go to step 16.