2–76 edge switch 2/16 service manual
Diagnostics
The problem is transient. The Fibre Channel link and the switch appear
operational.
26
Inspect the fiber-optic jumper cable attached to the port and ensure the cable is not
bent and connectors are not damaged. If the cable is bent or connectors are
damaged:
a. Notify the customer the port will be blocked. Ensure the customer system
administrator stops Fibre Channel frame traffic through the port and sets the
attached switch or device offline.
b. Block the port ("
Block a Port
" on page 3-39).
c. Remove and replace the fiber-optic jumper cable.
d. Unblock the port ("
Unblock a Port
" on page 3-39).
Was a corrective action performed?
YES NO
Go to step 28.
27
Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
The Fibre Channel link and switch appear operational.
28
Clean fiber-optic connectors on the jumper cable.
a. Notify the customer the port will be blocked. Ensure the customer’s system
administrator quiesces Fibre Channel frame traffic through the port and sets the
attached switch or device offline.
b. Block the port ("
Block a Port
" on page 3-39).
c. Disconnect both ends of the fiber-optic jumper cable.
d. Clean the fiber-optic connectors ("
Clean Fiber-Optic Components
" on page 3-33)
e. Reconnect the fiber-optic jumper cable.
f. Unblock the port ("
Unblock a Port
" on page 3-39).