HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
2–6 edge switch 2/16 service manual
Diagnostics
585 Primitive sequence timeout. Go to
MAP
0600
.
586 Invalid primitive sequence received
for link state.
Go to
MAP
0600
.
602 SBAR module anomaly detected. No action
required.
604 SBAR module failure. Go to
MAP
0600
.
605 SBAR module revision not supported. Go to
MAP
0600
.
800 High-temperature warning (port
module thermal sensor).
Go to
MAP
0500
.
801 Critically hot temperature warning
(port module thermal sensor).
Go to
MAP
0500
.
802 Port module shutdown due to thermal
violations.
Go to
MAP
0500
.
805 High-temperature warning (SBAR
module thermal sensor).
Go to
MAP
0500
.
806 Critically hot temperature warning
(SBAR module thermal sensor).
Go to
MAP
0500.
807 SBAR module shutdown due to
thermal violations.
Go to
MAP
0500
.
810 High-temperature warning (CTP
thermal sensor).
Go to
MAP
0500.
811 Critically hot temperature warning
(CTP thermal sensor).
Go to
MAP
0500
.
812 CTP shutdown due to thermal
violations.
Go to
MAP
0500
.
850 System shutdown due to CTP thermal
violations.
Go to
MAP
0500
.
Table 2–3: Event Codes versus Maintenance Action (Continued)
Event