HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
B–38 edge switch 2/16 service manual
Event Codes
SBAR Events (600 through 699)
NOTE: In the Edge Switch 2/16, the SBAR is not a separate assembly, therefore not a FRU. It
is an integral part of the switch’s main circuit board. SBAR failure requires replacement of the
entire switch.
Event Code: 602
Message: SBAR assembly anomaly detected.
Severity: Informational.
Explanatio
n:
Switch operational firmware detected a deviation in the normal operating mode or
operating status of the SBAR.
Action: No action required. An event code 604 is generated if the SBAR fails.
Event
Data:
Byte 0 = SBAR slot position (00 or 01) (not applicable).
Byte 1 = anomaly reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Byte 14 = participating SBAR assembly (not applicable).
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distributio
n:
Switch HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call-Hom
e
Sense
Info
Link
Incident
44