HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
B–34 edge switch 2/16 service manual
Event Codes
Event Code: 508
Message: Fibre Channel port anomaly detected.
Severity: Informational.
Explanatio
n:
The CTP detected a deviation in the normal operating mode or status of the indicated
Fibre Channel port.
Action: No action required. An event code 506 is generated if this anomaly results in a hard port
failure.
Event
Data:
Byte 0 = port number (00 through 63).
Byte 1 = anomaly reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Byte 14 = SBAR.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distributio
n:
Switch HAFM Server Host
EWS
Event
Log
System
Error
LED
Event
Log
E-Mail Call-Hom
e
Sense
Info
Link
Incident
44
Event Code: 510
Message: SFP optical transceiver hot-insertion initiated.
Severity: Informational.
Explanatio
n:
Installation of a small form factor pluggable (SFP) optical transceiver was initiated with
the switch powered on and operational. The event indicates that operational firmware
detected the presence of the transceiver.
Action: No action required.
Event
Data:
Byte 0 = port number (00 through 63).
Bytes 4 through 7 = elapsed millisecond tick count.