HP (Hewlett-Packard) A7284-96002 Switch User Manual


 
3–14 edge switch 2/16 service manual
Repair Information
Alert - If link incident (LIN) alerts are configured for the port through the
Configure Ports dialog box, a yellow triangle appears in the column when a link
incident occurs. A yellow triangle also appears if beaconing is enabled for the
port. A red and yellow diamond appears if the port fails.
Click anywhere in the port row to open the Port Properties dialog box. Right-click
anywhere in the port row to open a menu to:
Open the Port Properties dialog box.
Open the Node Properties dialog box.
Display the Port Technology dialog box.
Block or unblock the port.
Enable port beaconing.
Perform port diagnostics.
Enable or disable port channel wrapping. This menu option appears only when the
switch is configured for S/390 operating mode.
Swap one Fibre Channel port address with another. This menu option appears
only when the switch is configured for S/390 operating mode.
Clear link incident alerts.
Reset the port.
Configure Port Binding.
FRU List View
The FRU List View (Figure 3–8 on page 3-15) displays a list of all switch FRUs. The
information is useful to maintenance personnel for fault isolation and repair
verification.