Symbol Technologies SPT 1700 Scanner User Manual


 
20-10
SPT 1700 Series Product Reference Guide
Ethernet Cradle
The unit locks up with
all LEDs flashing red.
The unit could not configure
itself, or it lost its lease on one of
its ID addresses.
Hook the unit up to an Ethernet
network with a correctly functioning
DHCP server and 6 available IP
addresses.
General Issues
SPT 1700 terminal
does not turn on.
Adjust the contrast control.
Make sure the battery is charged
and installed properly.
Recharge the battery. If your SPT
1700 terminal still does not
operate, try a soft reset; refer to
Resetting Your SPT 1700 Terminal
on page 21-5 for details.
Low battery warning
after recharging the
batteries.
The battery warning message
may display immediately after
recharging the battery. In
addition, if you check the battery
gauge in the Applications
Launcher
immediately
after
recharging the battery, the gauge
may start at empty and slowly
rise to full.
This is normal. It takes a few
minutes for the battery gauge to
accurately show the condition of
the battery.
No sound. The System Sound option may
not be set correctly in the
General Preferences screen.
If the option is set to off, there will
be no sound. Refer to
General
Preferences
on page 14-10 for
more information.
No sound upon good
decode.
The System Sound option may
not be set correctly in the
General Preferences screen.
Verify that Beep on Good Decode
is set (checked) in Hardware Setup
in the Scan Demo Application.
Refer to
General Preferences
on
page 14-10 for more information.
SPT 1700 terminal
turns itself off.
Your SPT 1700 terminal is
designed to turn itself off after a
period of inactivity. This period
can be set at one minute, two
minutes or three minutes.
Check the Auto-off after setting in
the General Preferences screen,
and change the setting if you need
a longer delay before the automatic
shutoff feature activates. Refer to
General Preferences
on page 14-
10 for more information.
Problem Cause(s) Solution