Rogue AP Detection Commands
BreezeMAX Wi² and BreezeACCESS Wi² System Manual 233
Example
Related Commands
rogue-ap interval
(page 233)
5.19.4 rogue-ap interval
This command sets the interval at which to scan for APs.
Syntax
rogue-ap interval <minutes>
minutes - The interval between consecutive scans. (Range: 30-10080 minutes)
Default Setting
720 minutes
Command Mode
Interface Configuration (Wireless)
Command Usage
This command sets the interval at which scans occur. Frequent scanning will more readily detect
other APs, but will cause more disruption to client access.
Example
Related Commands
rogue-ap duration
(page 232)
5.19.5 rogue-ap scan
This command starts an immediate scan for APs on the radio interface.
Enterprise AP(if-wireless g)#rogue-ap duration 200
Enterprise AP(if-wireless g)#
Enterprise AP(if-wireless g)#rogue-ap interval 120
Enterprise AP(if-wireless g)#