Installation
BreezeMAX Wi² and BreezeACCESS Wi²
System Manual 25
2.3.3.3 Connecting to BreezeACCESS ODU with HW Revision E
1 Adapt the cable as described in Section 2.3.3.2
2 Connect the cable to the ODU as described in Section 2.3.3.1.
2.3.3.4 Connecting to BreezeACCESS ODU with HW Revision D or
Lower
1 Cut the cable as close as possible to the connector that should be connected to
the ODU (the end without the service box).
2 Route the cable through the service box supplied with the SU-ODU.
3 Connect the spare RJ-45 connector, supplied with the cable kit, as described
in step 2 of Section 2.3.3.2
4 Connect the Ethernet cable to the SU-ODU RJ-45 connector.
5 Make sure that the external jacket of the cable is well inside the service box to
guarantee a good seal.
6 Verify that the O-ring of the service box kit is in place, attach the service box to
the unit and tighten the top nut.
7 Connect the other end of the cable to the SU port on the Wi² unit.
8 Make sure that the external jacket of the cable is well inside the service box to
guarantee a good seal. Verify that the O-ring supplied with the service box is in
place, attach the service box to the unit and tighten the top nut.
Table 2-3: Cable Color Codes
Wire color Pin
Blue 1
Blue/white 2
Orange 3
Orange/white 6
Brown 4
Brown/white 5
Green 7
Green/white 8