Delta Electronics VFD-VE Series Network Card User Manual


 
Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04 4-57
01-27 S-curve for Deceleration Arrival Time 2 Unit: 0.1/0.01
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 0.2/0.0
Settings 0.00~25.00 sec /0.00~250.0 sec
It is used to give the smoothest transition between speed changes. The accel./decel. curve
can adjust the S-curve of the accel./decel. When it is enabled, the drive will have different
accel./decel. curve by the accel./decel. time.
The S-curve function is disabled when Pr.00-13 is set to 0.
The Actual Accel. Time = selected accel. Time + (Pr.01-24 + Pr.01-25)/2
The Actual Decel. Time = selected decel. Time + (Pr.01-26 + Pr.01-27)/2
01-24
01-25
01-26
01-27
Frequency
Time
01-28 Skip Frequency 1 (upper limit) Unit: 0.01
01-29 Skip Frequency 1 (lower limit) Unit: 0.01
01-30 Skip Frequency 2 (upper limit) Unit: 0.01
01-31 Skip Frequency 2 (lower limit) Unit: 0.01
01-32 Skip Frequency 3 (upper limit) Unit: 0.01
01-33 Skip Frequency 3 (lower limit) Unit: 0.01
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 0.00
Settings 0.00~600.00Hz
These parameters are used to set the skip frequency of the AC drive. The skip frequencies are
useful when a motor has vibration at a specific frequency bandwidth. By skipping this
frequency, the vibration will be avoided.
01-34 Mode Selection when Frequency< Fmin
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 0
Settings 0 Output Waiting
1
Zero-speed operation