Delta Electronics VFD-VE Series Network Card User Manual


 
Chapter 4 Parameters|
4-86 Revision August 2008, 03VE, SW V2.04
Settings 0 to 65535
Please refer to the explanation of Pr.02-00 to Pr.02-06.
MI4 MI3 MI2 MI1
Pr.10-19 setting 0 0 0 0 Master frequency
04-15 multi-position 1 0 0 0 1 04-00 1
st
step speed frequency
04-16 multi-position2 0 0 1 0 04-01 2
nd
step speed frequency
04-17 multi-position 3 0 0 1 1 04-02 3
rd
step speed frequency
04-18 multi-position 4 0 1 0 0 04-03 4
th
step speed frequency
04-19 multi-position 5 0 1 0 1 04-04 5
th
step speed frequency
04-20 multi-position 6 0 1 1 0 04-05 6
th
step speed frequency
04-21 multi-position 7 0 1 1 1 04-06 7
th
step speed frequency
04-22 multi-position 8 1 0 0 0 04-07 8
th
step speed frequency
04-23 multi-position 9 1 0 0 1 04-08 9
th
step speed frequency
04-24 multi-position 10 1 0 1 0 04-09 10
th
step speed frequency
04-25 multi-position 11 1 0 1 1 04-10 11
th
step speed frequency
04-26 multi-position 12 1 1 0 0 04-11 12
th
step speed frequency
04-27 multi-position 13 1 1 0 1 04-12 13
th
step speed frequency
04-28 multi-position 14 1 1 1 0 04-13 14
th
step speed frequency
04-29 multi-position 15 1 1 1 1 04-14 15
th
step speed frequency