Delta Electronics VFD-VE Series Network Card User Manual


 
Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04 4-17
Pr. Explanation Settings
Factory
Setting
VF VFPG
SVC
FOCPG
TQRPG
07-27
Source of Torque
Offset
0: Disable
1: Analog input (Pr.03-00)
2: Torque offset setting
3: Control by external terminal (by Pr.07-29 to Pr.07-
31)
0
07-28
Torque Offset Setting 0.0~100.0% 0.0
07-29
High Torque Offset 0.0~100.0% 30.0
07-30
Middle Torque Offset 0.0~100.0% 20.0
07-31
Low Torque Offset 0.0~100.0% 10.0
07-32
Forward Motor Torque
Limit
0~500% 200
07-33
Forward Regenerative
Torque Limit
0~500% 200
07-34
Reverse Motor Torque
Limit
0~500% 200
07-35
Reverse Regenerative
Torque Limit
0~500% 200
07-36
Emergency Stop (EF)
& Forced Stop
Selection
0: Coast stop
1: By deceleration Time 1
2: By deceleration Time 2
3: By deceleration Time 3
4: By deceleration Time 4
5: System Deceleration
6: Automatic Deceleration
0