Supply Chilled Water Over Temp 10047 1 Active on Alarm
Chilled Water Control Valve Position 10048 1 Active on Alarm
Supply Chilled Water Loss of Flow 10049 1 Active on Alarm
Supply Fluid Temp Sensor Issue 10050 1 Active on Alarm
Customer Input 1 10051 1 Active on Alarm
Customer Input 2 10052 1 Active on Alarm
Customer Input 3 10053 1 Active on Alarm
Customer Input 4 10054 1 Active on Alarm
Smoke Detected 10055 1 Active on Alarm
Water Under Floor 10056 1 Active on Alarm
Service Required 10057 1 Active on Alarm
Shutdown -Loss Of Power 10058 1 Active on Alarm
Ext Over Temperature 10059 1 Active on Alarm
Ext Loss of Flow 10060 1 Active on Alarm
Ext Condenser Pump High Water 10061 1 Active on Alarm
Ext Standby Glycol Pump On 10062 1 Active on Alarm
External Fire Detected 10063 1 Active on Alarm
Unit On 10064 1 Active on Alarm
Unit Off 10065 1 Active on Alarm
Unit Standby 10066 1 Active on Alarm
Unit Partial Shutdown 10067 1 Active on Alarm
Unit Shutdown 10068 1 Active on Alarm
Water Leakage Detector Sensor Issue 10069 1 Active on Alarm
BMS Communications Timeout 10070 1 Active on Alarm
Maintenance Due 10071 1 Active on Alarm
Maintenance Completed 10072 1 Active on Alarm
Clogged Air Filter 10073 1 Active on Alarm
RAM Battery Issue 10074 1 Active on Alarm
Master Unit Communication Lost 10075 1 Active on Alarm
High Power Shutdown 10076 1 Active on Alarm
Return Air Sensor Issue 10077 1 Active on Alarm
Condenser Outside Air Temp Sensor Issue 10078 1 Active on Alarm
Condenser Outside Air Temp Out of Operating Range 10079 1 Active on Alarm
Condenser Control Board Issue 10080 1 Active on Alarm
Condenser Refrigerant Pressure Over Threshold 10081 1 Active on Alarm
Condenser Refrigerant Pressure Under 10082 1 Active on Alarm
Condenser Refrigerant Pressure Sensor Issue 10083 1 Active on Alarm
Condenser Supply Refrigerant Over Temp 10084 1 Active on Alarm
Condenser Supply Refrigerant Under Temp 10085 1 Active on Alarm
Condenser Supply Refrigerant Temp Sensor Issue 10086 1 Active on Alarm
Condenser Max Fan Speed Override 10087 1 Active on Alarm
Condenser Fan Issue 1 - 4 10088-10091 1 Active on Alarm
Unspecified General Event 10100 1 Active on Alarm
Condenser Unit Unspecified General Event 10101 1 Active on Alarm
Condenser Circuit Unspecified General Event 10102 1 Active on Alarm
If the Scale column has a value for a Data Description, divide the Modbus value by the value in the Scale column to get the scaled value.
Table 11 Liebert CRV
- Status and Coil (continued)
Controller Liebert iCOM
®
v4
Data Label
Status Coil
Number
of Bits Scale Notes / Units