Finisar Surveyor Network Card User Manual


 
10-119
Expert Features
MAC Layer
10
Runt Frame
Counter
The Runt Frame counter increments when a frame is less than 64 bytes in length.
The Runt Frame counter is used for Expert Alarms. A count of all Runt Frames is
included in the Bad Frames counter that displays in the Overview counters of
Expert View.
Expert Symptom
Runt Frame events are automatically logged as expert symptoms. The
Symptom
Summary field contains the following information:
Runt frame has less than 64 bytes
Diagnostic Details
__________________________________________________________________
Problem Description:
A packet with less than 64 bytes of data has been received.
__________________________________________________________________
Probable Cause(s):
1. A faulty hub/switch/router device.
2. An end station may have a faulty network interface card.
3. A protocol analyzer has been transmitting error packets.
__________________________________________________________________
Recommended Action(s):
1. Find out the source device and fix the problem.