Finisar Surveyor Network Card User Manual


 
4-19
Configuring Surveyor
Settings for Analyzer Devices
4
2. Click on the icon for the remote analyzer device in the Resource Browser.
3. Choose
Properties from the Host menu.
4. Click the
Reset Host/Image Upgrade button.
5. Check the
Warm Boot radio button under Reset Options. Leave all other fields
blank or unmarked.
6. Click the
OK button.
When you reset a remote analyzer device, you will lose the connection. Use the
Connect option from the Remote menu to reconnect.
Updating an Analyzer Device
You can update the software or change address information for a Finisar analyzer
device from Surveyor.
Before you can reset the device with a new image, you must place the new image on
a server that runs TFTP protocol.
Download the new software from the support web site,
http://www.finisar.com. Go to the software updates section of the Web
site to find the new analyzer image. Place the software on the server that runs the
TFTP protocol.
Before you can update the analyzer address information automatically, you must
have a server that contains the new address information and runs the BOOTP proto-
col.
Use the following procedure to update the analyzer image software.
1. Login to the remote analyzer device with “super-user” privileges.
2. Click on the icon for the analyzer device in the Resource Browser.
3. Choose
Properties from the Host menu.
4. Set the new IP Address, IP Gateway Address, and Subnet Mask for the
analyzer. If no address update is needed, or you are updating the address from
a BOOTP server, skip this step.
5. Click the
Reset Host/Image Upgrade button.
6. Check the
Enable BOOTP box if you are updating addresses from a BOOTP
server.
7. Check the
Image Upgrade (TFTP) box if you are updating addresses from a
TFTP server.