Finisar Surveyor Network Card User Manual


 
4-11
Configuring Surveyor
System Settings
4
2. A dialog box appears showing the ports within the local system. Check the box
of only those ports you want Surveyor to scan for an analyzer card.
3. Click the
OK button.
Configuring Remote Communications
The remote server protocol (RSP) is used to control the interface for connecting
with remote systems. You configure the options that effect connection time outs,
encryption of control packets, and auto-discovery of resources.
To configure remote communications, select
System Settings… from the
Configuration menu. Select the Remote Communications tab.
Table 4-5. Remote Communications Tab Functions and Default Settings
Tab Selection Description
Encrypt RSP Packets check box Select encryption if there is a need for security in the network
when transferring packets between the remote resource and
the local system.
The default setting is Not Selected.
No Autodiscovery check box Select this box to prevent auto-discovery of remote resources.
If selected, you will only be able to access remote resources by
manual discovery of resources using the Connect option from
the Host menu. This box can be selected when working with
only local resources to eliminate viewing all resources in the
Resource Browser. The auto-discovery of resources may take
some time, especially in a large network.
The default setting is Not Selected
RSP Time Out value Specifies, in seconds, how long the protocol waits before drop-
ping a connection when the remote resource is not responding.
The value must be between 1 and 30 seconds.
The default setting is 10 seconds.