Finisar Surveyor Network Card User Manual


 
11-23
Multi-QoS
Field Descriptions for Call Details
11
Table 11-9. SIP Call Field Descriptions
Field Name Description
FID Frame ID of the first frame from which the conversation was detected. The
the frame ID of the first INVITE message.
Caller SIP URL or other URI of the caller. The addr-spec in the “From” parameter.
Caller Name Display name of the caller. The display name in the “From” parameter, if it
exists.
Caller Tag The tag of “From”, if it exists.
Caller Address The IP address of the initiator of the call.
Start Time Time at which the call was started, i.e. the time of the first INVITE message
of the call.
Stop Time Time at which the call was complete.
Setup Time (ms) Time that was taken for the call to be setup. This is the duration from
“INVITE” to the 180 or 183 (ringing) response if available, or to the 200
response otherwise. If none of these responses are received, the field
value is set to “Unknown”.
Call-ID Globally unique ID to identify a SIP call.
Callee SIP URL or other URI of the callee. The addr-spec in the “To” parameter.
Callee Name Display name of the callee. The display name in the “To” parameter, if it
exists.
Callee Tag The tag of “To”, if it exists.
Callee Address The IP address of the receiver of the call.
SIP Version The version of SIP being used.
Response Code The response code number from the callee.
Call Status Status of the call. An active call has the status of “Setting up” or “Set up
complete”, and a complete call has the status of “Set up failed”, “Aborted”,
“Complete”.