HP (Hewlett-Packard) CP4005 Printer User Manual


 
Control panel message Description Recommended action
PRINT CARTRIDGES
To exit press. Stop
Remove at least one
print cartridge.
To exit press. Stop
The printer is executing a disable cartridge
check or component test where the
component selected is the cartridge motor.
Remove one print cartridge.
REPLACE [COLOR]
CARTRIDGE
The supplies gauge will display the
consumption levels of print cartridges.
alternates with
The supplies gauge will display the
consumption levels of print cartridges.
The identified print cartridge has reached the
end of life and the COLOR SUPPLY OUT
setting in the SYSTEM SETUP menu is set
to STOP AT OUT. Printing can continue.
1. Order the appropriate print cartridge.
2. To continue, press
.
3. Open the front and top covers and then
open the image transfer unit.
CAUTION The image
transfer unit can be easily
damaged.
4. Remove the identified print cartridge.
5. Install a new print cartridge.
6. Close the image transfer unit and the top
and front covers.
7. Supplies ordering information is also
available from the embedded Web
server. See
Using the embedded Web
server for more information.
REPLACE FUSER KIT
For help press
The fuser kit has reached the end of its life.
Replace the fuser kit. Printing can continue
although print quality might be reduced.
1. Open the top cover.
2. Grasp the purple handles on the fuser
unit.
3. Remove the old fuser unit from the
printer.
4. Install a new fuser unit and secure with
thumb screws.
5. Close the top cover.
6. Supplies ordering information is also
available from the embedded Web
server. See
Using the embedded Web
server for more information.
REPLACE FUSER KIT
For help press
alternates with
REPLACE FUSER KIT
The fuser is nearing the end of its useful life
and the REPLACE SUPPLIES setting in
the SYSTEM SETUP menu is set to STOP
AT OUT. Printing can continue.
1. Order the fuser kit.
2. To continue printing, press
.
3. To replace the fuser kit, perform the
following steps:
Open the top cover.
Grasp the purple handles on the
fuser unit.
ENWW Control panel messages 177