Honeywell MX9 Laptop User Manual


 
6 - 8
Auto Re-Launch
Default is Enabled.
When enabled for a specific application. automatically re-launches it (subject to the specified Auto Re-Launch Delay in
seconds) after it terminates. This option allows the Administrator to disable the re-launch operation. AppLock cannot
prevent all applications from closing. When an application that AppLock cannot prevent from closing terminates, per-
haps because of an error condition, AppLock re-launches the application when this option is enabled.
Note: If Allow Close is enabled and both Auto Re-launch and Manual (Launch) are disabled, the application cannot be
restarted for the end-user or by the end-user after the application terminates.
Retries
Default is 0 tries. Retries is the number of times AppLock will try to re-launch the application. The retry count is reset
after an application is successfully launched and controlled by AppLock. Valid values are between 0 (no tries) and 99
tries or -1 for infinite. Infinite tries ends when the application successfully launches.
Delay
Default is 0 seconds (no delay). Delay is the amount of time AppLock waits prior to re-launching an application that has
terminated. The delay is specified in seconds. Valid values are between 0 (no delay) and 99 seconds.
AppLock must also be configured to automatically re-launch an application. To AppLock, application termination by the
end-user is indistinguishable from application termination for any other reason.
Manual (Launch)
Default is Disabled.
Enabling this option allows the end-user to launch the specified application(s). Upon bootup completion an application
with Manual enabled is listed on the Switchpad accompanied by a check mark that indicates the application is currently
active or available for Launching. When an application name is tapped by the end-user, the application is launched (if
inactive) and brought to the foreground.
Applications set up with Manual (Launch) enabled may or may not be launched at bootup. This function is based on the
application’s Auto At Boot setting. The applications have been listed as approved applications for end-user manual
launch using the Switchpad menu structure. The approved applications are listed on the Switchpad. A check mark indi-
cates the applications active status.
When Manual (Launch) is disabled for an application, and Allow Close is enabled for the application, when the end-
user closes the specific application it is no longer available (shown) on the Switchpad.
When Auto At Boot and Manual (Launch) are both disabled for a specific application, the application is 1) not placed on
the list of approved applications for end-user manual launch and 2) never launched, and 3) not displayed on the
Switchpad.
Match
Default is blank (Match is not used).
AppLock works by associating display windows with the launched process ID. If an application uses different process
IDs for windows it creates, the Match field must be used.
Use the Match field to specify up to 32 characters of the class name for the application.
DOS applications using a standard DOS display box should specify condev_appcls in the Match text box.
Remote Desktop (remote.exe) should specify TSSHELLWND in the Match text box.