13 - 15
DC/DC Power Supply Installation, Screws on Side of Lid
For use with
• 9000311PWRSPLY – Power Supply, 9-60VDC, 60W
• 9000313PWRSPLY – Power Supply, 50-150VDC, 60W:
If your DC/DC power supply does not look like the image above, see DC/DC Power Supply Installation, Screws on Top of
Lid (page 13-18) for installation instruction.
Connecting Electrical Cables to Power Sources
The DC/DC power supply is used to provide vehicle power to the MX9 when it is placed in a DC powered vehicle
cradle.
Specifications for Electrical Supply
Note: Refer to the Wiring Schematic that follows for wiring colors and connections.
Shown With Lid Attached
• Lid is secured with screws on the side of lid.
Shown With Lid Removed
• Input and output connector blocks under lid.
• One positive (Vin+), negative (Vin-) and ground
( ) connection in input block.
• One positive (Vo+) and negative (Vo-) connection in
output block.
Input Voltage Always observe input voltage range specified for the DC/DC power supply.
Output Voltage 13.5 VDC ± 10%
Fuse 5 A (slow blow fuse). Fuses are USER SUPPLIED
Caution: For proper and safe installation, the input power cable must be connected to a fused circuit on the
vehicle. This fused circuit requires a five Amp maximum time delay (slow blow) high interrupting
rating fuse. If the supply connection is made directly to the battery, the fuse should be installed in the
positive lead within 5 inches of the battery positive (+) terminal. Note: For North America, a UL
Listed fuse is to be used.
Caution: Usage in areas where moisture can affect the power supply connections should be avoided. The
power supply should be mounted in a dry location within the vehicle or placed in a suitable protective
enclosure.
Caution: For installation by trained service personnel only.
!
!
!