Intel SSR212PP Network Card User Manual


 
120 Intel Storage System SSR212PP User Guide
Revision 1.0
PRELIMINARY
Conguring iSCSI Initiators for Linux or Windows
Congurations without iSNS
If you are using Windows with iSNS, this section is not for you. Instead, go to
"Configuring the iSNS Client on the Storage System" on page 124.
Before an iSCSI initiator can send data to or receive data from the storage system, you
must configure the network parameters for the NIC orHBA iSCSI initiators to connect
with the storage-system SP iSCSI targets.
If the storage system already has NIC orHBA iSCSI initiators to connect with the storage-
system SP iSCSI targets.
Conguring Windows NIC Initiators to Connect to iSCSI Targets
Use the Navisphere Server Utility to configure the network parameters for each NIC
initiator that needs access to the storage system.
The Microsoft iSCSI Initiator gives the same name to all NICs in a server. This
name identifies the server, not the individual NICs, to a storage-system SP. This
means that if multiple NICs from the same server are connected to an SP only one
NIC is actually used. Other NICs are in standby mode. If you leave the Server
Network Adapter IP option set to Default, the server will use one of the other NICs
if the first NIC fails.
STEP 1. On the server, open the Navisphere Server Utility. See Procedure 30, "Running the
Navisphere Server Utility," on page 165.
STEP 2. Select Congure iSCSI Connections on this server and click Next.
STEP 3. Select Congure iSCSI Connections and click Next.
STEP 4. In the iSCSI Targets and Connections window, select one of the following options to
discover the iSCSI target ports on the connected storage systems:
Discover iSCSI targets on this subnet scans the current subnet for all connected
SSR212PP-Series iSCSI storage system targets. The utility scans the subnet in the
range from 1 to 255. For example, if the current subnet is
10.12.77, the utility will
scan the IP addresses from
10.12.77.1 to 10.12.77.255.
If CHAP authentication is enabled on all target ports on a storage system,
you cannot discover using a subnet scan. You must discover the targets using
the target portal.
Discover iSCSI targets for this target portal discovers targets known to the specified
iSCSI SP data port.
STEP 5. Click Next. If you entered the IP address of the iSCSI target and you have CHAP
authentication enabled on that target, the CHAP login windows displays. Enter the CHAP
security information (username and secret) and if you have mutual CHAP configured on